Solafact 820

Solafact 820

Product Introduction
SOLAFACT 820 is a nuclear detection UAV. The flight platform is DJI’s industry-level Matrice M300 RTK UAV. SiPM’s nuclear detection technology can detect trace chemical agents, industrial toxic and harmful gases and radioactive pollution online, quickly and accurately.The results of nuclear chemical reconnaissance and detection can be displayed in real time on the UAV control terminal through transparent transmission. The professional visual analysis software can be seamlessly connected with nuclear chemical reconnaissance and inspection drones to achieve second-level response and draw nuclear and chemical pollution in real time. The three-dimensional pollution concentration distribution in the area is clear at a glance, and the pollution source can be quickly identified.

Features

  • Unmanned nuclear radiation and chemical hazard detection.
  • Support AIS, GPS, GLONASS and GALILEO positioning and navigation functions.
  • Visualization, providing a high-definition 3D map of the surrounding environment.
  • Conduct safety assessments of dangerous areas in advance from a safe distance.
  • Qualitative and quantitative detection of pollutants and mapping the distribution range of pollutants.
  • The gimbal quickly surveys and draws the surrounding map from the air to assess the hazards of entering the site.
  • Comprehensive understanding of the regional scene, including visual and nuclear contamination.
  • Quickly formulate protective measures, direction of travel and treatment methods for entering dangerous sites.
  • Significantly reduces reconnaissance time before taking action.
Technical Specifications:
Parameter Name
Performance Parameters
Image transmission distance
≥ 15km
Flight radius
≥ 7.5km
Longest flight time
55 mins
Maximum flight altitude
7km
Maximum flight speed
23 m/s
Avoidance
Intelligent six-way positioning
Operating temperature
-40℃ to 52℃
Nuclear detection indicators:
.
Examination range
0.01uSv/h~10mSv/h
Detection accuracy
±10%
Energy response
±10%
Detection source type
35KeV-1.5MeV
Detector technology type
Scintillation crystal +SiPM
Chemical testing indicators:
.
Sarin
0.1mg/m3
Soman
0.2mg/m3
Lewisite
0.2mg/m3
Tabun
0.2mg/m3
Viex
0.2mg/m3
Mustard gas
1mg/m3
Hydrocyanic acid
10mg/m3
Cyanogen chloride
10mg/m3
Phosgene
10mg/m3
Ammonia
10mg/m3
Chlorine
20mg/m3
Sulfur dioxide
10mg/m3
Hydrogen sulfide
10mg/m3
Hydrogen chloride
20mg/m3
Nitrogen dioxide
10mg/m3
Carbon monoxide
10mg/m3
Hydrofluoric acid
10mg/m3
Application Area

It can be widely used in chemical defense reconnaissance, hazardous chemical explosion site, industrial park inspection, nuclear power plant leak detection, environmental protection and other fields.

Scroll to Top